Section 8 · GC
Ground coupling
Not runSlab-on-grade heat transfer to the ground, compared with analytical and detailed numerical solutions.
Not run in this release
No case of this suite was run. Block E of the modeler report lists the omitted cases and the reason for each.
ASoftware information
1. SOFTWARE VENDOR:
Jared Bell, Roots Ontological Technologies, LLC
2. SOFTWARE NAME:
SIMsara
3. SOFTWARE VERSION (unique software version identifier):
SIMsara 0.1.0
4. OPERATING SYSTEM REQUIREMENTS:
macOS 13 or later on Apple silicon (arm64). This is the build that was
tested; other targets are listed only when they have been built and run
for these tests.
5. APPROX HARD DISK SPACE REQUIRED FOR INSTALLATION:
About 6.1 MB: the release binary s140_run, which needs no other runtime
files beyond the TOML input and the EPW weather file.
6. MINIMUM RAM REQUIRED FOR SOFTWARE OPERATION:
16 MB: the largest peak resident memory of any submitted test case,
measured with /usr/bin/time -l on the tested build.
7. MINIMUM DISPLAY MONITOR REQUIREMENTS:
None. SIMsara is a command-line program with no graphical display.
8. OTHER HARDWARE OR SOFTWARE-RELATED REQUIREMENTS:
Input is TOML (docs/TOML-INPUT.md in the source distribution) with EPW
weather. Building from source needs Rust 1.98.1. The Standard 140 harness
scripts that generate the test inputs and fill the output templates need
Python 3.11 or later, standard library only.BAlternative modeling methodsNone
NONE
CEquivalent modeling methodsNone
NONE
DUse of non-specified inputs
* Alternative constant exterior surface coefficients in Sections 7.2.1.9.3, 7.2.3.1.4.3, 7.2.3.3.2, and 9.2.1.8 * Alternative constant interior surface coefficients in Sections 7.2.1.10.3, 7.2.3.1.4.4, 7.2.3.2.2, and 9.2.1.9 * Alternative constant interior solar distribution fractions in Sections 7.2.1.12, 7.2.2.1.2.2, 7.2.2.1.6.2, 7.2.2.1.7.2, 7.2.2.2.7.4, 7.2.3.9.3, 7.2.3.10.2, and 7.2.3.12.2 * Air density given at specific altitudes for the space-cooling and space- heating equipment cases in Sections 9.2.1.4.3, 9.2.3.4.3, and 10.2.1.4.3. NONE
EOmitted test cases and results
NOTE 1 - Ground-Coupled Slab-on-Grade Cases, All Results (Section 8)
-------------------------------------------------------------------------------
1.1 List the Case(s) where Results Were Omitted, and which Results Were Omitted
for the Case(s):
GC10a, GC30a, GC30b, GC30c, GC40a, GC40b, GC40c, GC45b, GC45c, GC50b,
GC55b, GC55c, GC60b, GC65b, GC70b, GC80b and GC80c: all results are
omitted.
1.2 Explanation for Omitting the Test Case(s) Results:
SIMsara has no transient two- or three-dimensional ground conduction model
with deep-ground and far-field boundary conditions; it does not accept
user-specified constant interior and exterior surface coefficients or fixed
surface temperatures as these cases require; and a run is limited to one
year, whereas these cases require multi-year simulations. No input files
for these cases are supplied with the accompanying files (the input-file
folder holds only a link to externally hosted files), so SIMsara inputs
would have to be developed from the specification text, which is deferred
until the ground model exists.FChanges to source codeNone
NONE
GAnomalous resultsNone
NONE
Rendered from S140outNotes-SIMsara-GC.txt, the modeler report in the form Standard 140 prescribes. The template's own instructions are left out here.
The filled output template and the results workbook are the official record. They hold ASHRAE's licensed template content and are not published here.